Modelul Axis I5304 face parte din gama 2N, categoria „Intercoms”.
Specificațiile detaliate pentru Axis I5304 se preiau zilnic din catalogul 2N și apar aici imediat ce sunt publicate.
2N oferă pentru Axis I5304 firmware-ul V3.2.0, lansat la 21.05.2026. Fișierul se descarcă direct de pe serverele 2N; IPCCTV nu găzduiește firmware.
Firmware-ul se încarcă de obicei din interfața web a aparatului sau din software-ul de administrare al producătorului.
| Versiune | Data | Regiune | Descărcare și note |
|---|---|---|---|
| V3.2.0Firmware 3.2.0 - Axis I5304 | 21.05.2026 | Global | 35 MB Note de versiuneSHA-256: 6551ea83efcd0d0f0a8e04aa941342cd452dc6bc6edff4e3a34f564d178fda26 Fișier: firmware_3_2_0_axis_i5304.zip Firmware version 3.2.0 for AXIS Access Control Readers includes the following changes Essential Corrections Improved configuration import speed and stability. Updated several internal libraries. Important bug fixes. |
| Versiune | Data | Regiune | Descărcare și note |
|---|---|---|---|
| V3.1.0Firmware 3.1.0 - Axis I5304 | 04.03.2026 | Global | 35 MB Note de versiuneSHA-256: 969005c236a1e7bd796ec6d8d2085763fb8873c1e81a96037e4044f9d09467ae Fișier: firmware_3_1_0_axis_i5304.zip Firmware version 3.1.0 for AXIS Network Answering Units includes the following changes Precautions to be taken during update to FW version 3.1.x Devices no longer emit audible beeps during boot or network state changes by default. If required, this behavior can be enabled under `Customization > Audio > Startup and Network States Signalization`. It may be necessary to refresh the webpage to access the login screen when updating from older firmware because this version generates new device certificates. New Functions and Improvements The Control Center feature has been significantly expanded. It now supports the following widgets: HTTP requests, Clock, Weather, Direct Call, and Notification Center. Widgets now come in more sizes, and the grid density has increased to allow for more placement options. Essential Corrections SIP registration should no longer get stuck in an unregistered state. A voicemail message is no longer played in SIP calls after an unlock if the call was not answered first. Updated several internal libraries. Other corrections and fixes. |
| V3.0.2Firmware 3.0.2 - Axis I5304 | 31.12.2025 | Global | 34 MB Note de versiuneSHA-256: 489bbd03b79df61909a7cf6e344aed50798c6ef45fe7e479d10c1bfd17d78a4c Fișier: firmware_3_0_2_axis_i5304.zip Firmware version 3.0.2 for AXIS Network Answering Units includes the following changes Essential Corrections Important bug fixes. Firmware version 3.0.0 for AXIS Network Answering Units includes the following changes Precautions to be taken during update to FW version 3.0.x Devices can no longer be downgraded below version 2.47.0 after updating. Devices no longer accept certificates signed with 1024-bit RSA keys. These certificates are removed during the update and must be replaced with certificates using at least 2048-bit RSA or ECC keys. Services relying on weaker certificates will stop functioning, and a warning will appear next to the certificate selection parameter in the web interface. In EAP-TLS mode, 802.1x no longer supports RADIUS certificates containing the `id-kp-clientAuth` Extended Key Usage. If such certificates are used, they will be rejected after the update, resulting in the device being unable to authenticate and connect to the network. New Functions and Improvements Reception of `In-Band (Audio)` DTMF is now disabled by default to improve resilience against malicious attacks. Added support for Blind Assistance Mode during incoming calls. In this mode, all controls—both physical buttons and the display—perform identical actions. A short press answers an incoming call or ends an active call, while a long press unlocks the door once the call is connected. This mode is intended for visually impaired users and should not be used together with Screen Lock. STUN support has been added and can be configured under `Calling > SIP # > Configuration`. Added support for the Japanese language in the display UI. The custom language name defined in the translation file is now displayed in the Display UI instead of the generic "Custom" label. Essential Corrections Updated several internal libraries. Cached DNS entries for SIP registrars now expire immediately and correctly when the registrar IP address changes, preventing registration failures. A voicemail message is no longer played after a successful door unlock if the call was not answered. Devices now correctly process `Too Brief` SIP responses during registration and immediately apply the updated expiry period. Eliminated a condition that could cause SIP registration to become permanently stuck in the unregistered state. Other corrections and fixes. |
| V2.49.1.75Firmware 2.49.1.75 - Axis I5304 | 23.10.2025 | Global | 32 MB Note de versiuneSHA-256: 8864efb9e5764097b4f7cdb5a7e58d0f2cd3d26b79208ed0d0515493d0208246 Fișier: firmware_2_49_1_axis_i5304.zip Firmware version 2.49.1 for AXIS Network Answering Units includes the following changes Essential Corrections Updated an internal library containing critical vulnerabilities. Fixed a critical issue with DNS which caused the device to, e.g., become unable to re-register to a SIP server after its IP address changes. This also solved other DNS-related issues. Important bug fixes. Firmware version 2.49.0 for AXIS Network Answering Units includes the following changes Precautions to be taken during update to FW version 2.49.x Empty device names are no longer supported. Set the name via Services > Web Server > Device Name. If left blank, the device may fail to update. Devices can no longer be downgraded below version 2.47.0 after updating. Devices no longer accept certificates signed with 1024-bit RSA keys. These certificates are removed during the update and must be replaced with certificates using at least 2048-bit RSA or ECC keys. Services relying on weaker certificates will stop functioning, and a warning will appear next to the certificate selection parameter in the web interface. In EAP-TLS mode, 802.1x no longer supports RADIUS certificates containing the `id-kp-clientAuth` Extended Key Usage. If such certificates are used, they will be rejected after the update, resulting in the device being unable to authenticate and connect to the network. New Functions and Improvements AXIS I5304 now includes an optional Control Center screen, providing access to additional HTTP commands and widgets such as date and time. It can be enabled and customized under Services > Control Center. This feature allows you to define which screen appears when the device wakes—either the classic home screen or the customizable Control Center. The second screen remains accessible with a simple swipe. A background image that is common to both the Home Screen and Control Center can be uploaded via Hardware > Display > Background Image. Native integration with Microsoft Teams has been added, allowing bidirectional calling with our devices and enabling door unlocking directly from the Teams client. Configuration is available via Services > Integration > MS Teams. Essential Corrections Updated several internal libraries. Increased stability of AXIS I5304 during repeated calls. Syslog now correctly logs initial packets after reboot. Improved overall SIP performance and stability. Important bug fixes. |
| V2.48.1Firmware 2.48.1 - Axis I5304 | 23.10.2025 | Global | 30 MB Note de versiuneSHA-256: 16b2e2db95b0bca7cda53503e2f4c85b4d7602335119374a4d0922f294fc683e Fișier: firmware_2_48_1_axis_i5304.zip Firmware version 2.48.1 for AXIS Network Answering Units includes the following changes Precautions to be taken during update to FW version 2.48.x Devices can no longer be downgraded below version 2.47.0 after updating. Devices no longer accept certificates signed with 1024-bit RSA keys. These certificates are removed during the update and must be replaced with certificates using at least 2048-bit RSA or ECC keys. Services relying on weaker certificates will stop functioning, and a warning will appear next to the certificate selection parameter in the web interface. In EAP-TLS mode, 802.1x no longer supports RADIUS certificates containing the `id-kp-clientAuth` Extended Key Usage. If such certificates are used, they will be rejected after the update, resulting in the device being unable to authenticate and connect to the network. New Functions and Improvements Devices can now generate Certificate Signing Requests (CSR) directly from the web interface under System > Certificates > CSR. All SIP accounts now support additional backup proxy and registrar servers. Changing the web interface password now requires entering the current password. As a result, restoring a configuration will no longer change the password. Auto Provisioning can change the password only if the current one is still set to default. Cameras assigned to a device in Indoor View can now be shown as the default instead of the device’s internal camera. Third-party cameras can be added via Hardware > Cameras, and the display behavior adjusted under Directory > Devices > device detail > Cameras. Essential Corrections Improved certificate handling. Prevented some certificates from reverting to factory defaults after a software factory reset (without selecting Network Settings), avoiding potential network disconnection. SIP unregistration now works correctly with non-RFC-compliant User Agent Servers. Removed certain unnecessary syslog messages. Improved formatting of exported Directory CSV files. SIP authentication passwords can now be up to 255 characters in length. DNS request lengths can now be up to 255 characters. RADIUS certificates are now validated properly in EAP-TLS/MSCHAPv2 scenarios. Fixed device crashes caused by missing Origin fields in SDP offers. SRTP media is now correctly offered in the ACK response when using delayed SDP negotiation enforced via options. When SRTP is re-negotiated during a RE-INVITE, the newly established encryption key is now properly applied to outgoing media streams. Improved stability of the G.729 codec. Important bug fixes. |
Videointerfon2N Audio KitFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP BaseFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP ForceFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP Force 2.0Firmware V3.3.1 · 31.08.2026
Videointerfon2N IP OneFirmware V3.3.1 · 31.08.2026
Videointerfon2N IP SafetyFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP SoloFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP StyleFirmware V3.3.1 · 31.08.2026
Videointerfon2N IP UniFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP VarioFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP VersoFirmware V2.50.2 · 02.10.2026
Videointerfon2N IP Verso 2.0Firmware V3.3.1 · 31.08.2026