2N 2N LiftIP 2.0 este un dispozitiv de videointerfon, listat de producător la „Elevator systems”.
Pe scurt, aparatul are alimentare PoE (802.3af).
La ultima verificare, cel mai nou firmware pentru 2N LiftIP 2.0 era V3.3.1 (31.08.2026). Pagina se actualizează zilnic din lista oficială 2N.
Firmware-ul se încarcă de obicei din interfața web a aparatului sau din software-ul de administrare al producătorului.
Tabelul de specificații de mai jos conține toate datele tehnice publicate de producător, traduse în română.
| Versiune | Data | Regiune | Descărcare și note |
|---|---|---|---|
| V3.3.1Firmware 3.3.1 - 2N Lift IP 2.0 | 31.08.2026 | Global | 18 MB Note de versiuneSHA-256: 1532627a666cda85c37b3140a6839fce8721e0366b65ddcf7f1cfdaed7ec68f8 Fișier: firmware_3_3_1_2n_lift_ip_2.zip 2N OS version 3.3.1 for 2N Elevator Systems includes the following changes Essential Corrections Updated several internal libraries. Important bug fixes. 2N OS version 3.3.0 for 2N Elevator Systems includes the following changes New Functions and Improvements Firmware management has been consolidated into a new dedicated section: System > Firmware, including firmware auto provisioning settings. Automatic firmware updates — firmware can now be updated automatically on device startup or on a configurable periodic schedule. LTS track support — devices can now be assigned to a Long-Term Support firmware track. Auto provisioning for answering units — firmware auto provisioning is now supported on answering units as well. Added an option to disable all on-device firmware operations entirely. Essential Corrections The `SendHttpRequest` Automation block now correctly encodes unsafe characters using percent encoding. To send the backslash `\` and comma `,` characters, they must be escaped with a preceding backslash `\`, otherwise they are used for escaping and separating parameters, respectively. For example, to send a command containing this text: `https://127.0.0.1/axis-cgi/io/port.cgi?action=2:\`, the backslash must be escaped with a `\` as follows: `https://127.0.0.1/axis-cgi/io/port.cgi?action=2:\\`. This results in a correctly encoded HTTP command: `https://127.0.0.1/axis-cgi/io/port.cgi?action=2%3A%5C`. Fixed a time profile-related crash in the user detail view of the new web interface. Updated several internal libraries. Important bug fixes. |
| Versiune | Data | Regiune | Descărcare și note |
|---|---|---|---|
| V3.3.0Firmware 3.3.0 - 2N Lift IP 2.0 | 05.08.2026 | Global | 18 MB Note de versiuneSHA-256: dcffe4fc4c16123f9688d865cf99eb9cb95d3d2ea06d42d2dfe9ac74cff6bde0 Fișier: firmware_3_3_0_2n_lift_ip_2.zip 2N OS version 3.3.0 for 2N Elevator Systems includes the following changes New Functions and Improvements Firmware management has been consolidated into a new dedicated section: System > Firmware, including firmware auto provisioning settings. Automatic firmware updates — firmware can now be updated automatically on device startup or on a configurable periodic schedule. LTS track support — devices can now be assigned to a Long-Term Support firmware track. Auto provisioning for answering units — firmware auto provisioning is now supported on answering units as well. Added an option to disable all on-device firmware operations entirely. Essential Corrections The `SendHttpRequest` Automation block now correctly encodes unsafe characters using percent encoding. To send the backslash `\` and comma `,` characters, they must be escaped with a preceding backslash `\`, otherwise they are used for escaping and separating parameters, respectively. For example, to send a command containing this text: `https://127.0.0.1/axis-cgi/io/port.cgi?action=2:\`, the backslash must be escaped with a `\` as follows: `https://127.0.0.1/axis-cgi/io/port.cgi?action=2:\\`. This results in a correctly encoded HTTP command: `https://127.0.0.1/axis-cgi/io/port.cgi?action=2%3A%5C`. Fixed a time profile-related crash in the user detail view of the new web interface. Updated several internal libraries. Important bug fixes. |
| V3.2.0Firmware 3.2.0 - 2N Lift IP 2.0 | 21.05.2026 | Global | 18 MB Note de versiuneSHA-256: 61604237bd5c0dea463832fb655b242219b6c6c1c90d4826bef3ee74f71ea22d Fișier: firmware_3_2_0_2n_lift_ip_2.zip 2N OS version 3.2.0 for 2N Elevator Systems includes the following changes New Functions and Improvements Added support for hiding and swapping icon positions for Sentrio Cabin in `Hardware > Display > Buttons`. Added support for SHA-256 / RFC 8760 to SIP. Essential Corrections Fixed a memory leak in Automation. Improved configuration import speed and stability. Fixed an issue where Sentrio Cabin sent an INVITE with a video offer even when no external camera was present. Updated several internal libraries. Important bug fixes. |
| V3.1.0Firmware 3.1.0 - 2N Lift IP 2.0 | 03.03.2026 | Global | 18 MB Note de versiuneSHA-256: 38acdaba3f300b728725e0a1b2e36eab45ad498ec7f5d824701f084fc97c79d2 Fișier: firmware_3_1_0_2n_lift_ip_2.zip 2N OS version 3.1.0 for 2N Elevator Systems includes the following changes Precautions to be taken during update to FW version 3.1.x Devices no longer emit audible beeps during boot or network state changes by default. If required, this behavior can be enabled under `Customization > Audio > Startup and Network States Signalization`. It may be necessary to refresh the webpage to access the login screen when updating from older firmware because this version generates new device certificates. New Functions and Improvements CCURE support added. Essential Corrections Fixed the detection algorithm for logical loops in Automation. SIP registration should no longer get stuck in an unregistered state. Updated several internal libraries. Other corrections and fixes. |
| V3.0.2Firmware 3.0.2 - 2N Lift IP 2.0 | 19.02.2026 | Global | 18 MB Note de versiuneSHA-256: 8a5045272b6ddbb2d33322adb60d3960a7381db3c3c4f4d30cc48c112117523b Fișier: firmware_3_0_2_2n_lift_ip_2.zip 2N OS version 3.0.2 for 2N Elevator Systems includes the following changes Essential Corrections Important bug fixes. 2N OS version 3.0.0 for 2N Elevator Systems includes the following changes Precautions to be taken during update to FW version 3.0.x For security reasons, network settings can no longer be modified using 2N Network Scanner. All 2N OS devices (except those on the original platform: IP Vario, IP Force, IP Safety, IP Solo, IP/LTE Verso, IP Base, IP Uni, IP Audio Kit, IP Video Kit, Access Unit, SIP Speaker) can no longer be downgraded below version 2.47.0 after updating. Devices no longer accept certificates signed with 1024-bit RSA keys. These certificates are removed during the update and must be replaced with certificates using at least 2048-bit RSA or ECC keys. Services relying on weaker certificates will stop functioning, and a warning will appear next to the certificate selection parameter in the web interface. New Functions and Improvements Reception of `In-Band (Audio)` DTMF is now disabled by default to improve resilience against malicious attacks. Default values and ranges for `Calling > Alarm Call > Test Alarm` parameters have been updated. `Enable` is now set to TRUE by default, and `Press Duration to Activate` now accepts values from 5 to 60 seconds. STUN support has been added and can be configured under `Calling > SIP # > Configuration`. The custom language name defined in the translation file is now displayed in the Display UI instead of the generic "Custom" label. Essential Corrections Updated several internal libraries. Web configuration pages for Automation features now load correctly even when the device is offline (without an active internet connection). Resolved a device crash that could occur when sending emails using specific SMTP server configurations. The `snmpget` function now works correctly on devices using SNMPv3. Devices now correctly process `Too Brief` SIP responses during registration and immediately apply the updated expiry period. Other corrections and fixes. |
| V2.49.1.75Firmware 2.49.1.75 - 2N Lift IP 2 | 23.10.2025 | Global | 19 MB Note de versiuneSHA-256: 2b10cd3c6b8a4d4860b606dab28ec9a8c213ab12050003bd1669ca941620b400 Fișier: firmware_2_49_1_2n_lift_ip_2.zip 2N OS version 2.49.1 for 2N Elevator Systems includes the following changes Essential Corrections Updated an internal library containing critical vulnerabilities. Fixed a critical issue with DNS which caused the device to, e.g., become unable to re-register to a SIP server after its IP address changes. This also solved other DNS-related issues. Important bug fixes. 2N OS version 2.49.0 for 2N Elevator Systems includes the following changes Precautions to be taken during update to FW version 2.49.x Empty device names are no longer supported. Set the name via Services > Web Server > Device Name. If left blank, the device may fail to update. All 2N OS devices (except those on the original platform: IP Vario, IP Force, IP Safety, IP Solo, IP/LTE Verso, IP Base, IP Uni, IP Audio Kit, IP Video Kit, Access Unit, SIP Speaker) can no longer be downgraded below version 2.47.0 after updating. Devices no longer accept certificates signed with 1024-bit RSA keys. These certificates are removed during the update and must be replaced with certificates using at least 2048-bit RSA or ECC keys. Services relying on weaker certificates will stop functioning, and a warning will appear next to the certificate selection parameter in the web interface. New Functions and Improvements The administrator account now accepts "root" as a valid username as well. AXIS Camera Station integration has been significantly improved: The ACS tab in the web interface is now renamed to AXIS. AXIS Camera Station integration is now always enabled and accessible using the device's administrator account. After the initial login to the web interface, the "root" username can also be used for ACS access. An optional dedicated ACS account is now available. If ACS was previously enabled with both username and password configured, the dedicated account can still be used. If your dedicated ACS account used "admin" or "root" as the username and had the same password as the administrator account, it will be merged with the administrator account and you can continue using the same credentials. If your dedicated ACS account used "admin" or "root" but had a different password from the administrator account, it will be migrated to a temporary administrator account. You can continue using the same credentials, and the account will be merged with the administrator account after its password is updated. 2N IP Utility can now also be used to configure IP settings after the default password has been changed. Lift products can now dial up to 6 destinations per user, increased from the previous limit of 3. Native integration with Microsoft Teams has been added, allowing bidirectional calling with our devices and enabling door unlocking directly from the Teams client. Configuration is available via Services > Integration > MS Teams. Essential Corrections Updated several internal libraries. Enhanced |
| V2.48.1Firmware 2.48.1 - 2N Lift IP 2 | 06.08.2025 | Global | 17 MB Note de versiuneSHA-256: 16822312d9706be5de99b4446c3d564d0a2539427bdb45022d6a21b210daef9a Fișier: firmware_2_48_1_2n_lift_ip_2.zip 2N OS version 2.48.1 for 2N Elevator Systems includes the following changes Precautions to be taken during update to FW version 2.48.x All 2N OS devices (except those on the original platform: IP Vario, IP Force, IP Safety, IP Solo, IP/LTE Verso, IP Base, IP Uni, IP Audio Kit, IP Video Kit, Access Unit, SIP Speaker) can no longer be downgraded below version 2.47.0 after updating. Devices no longer accept certificates signed with 1024-bit RSA keys. These certificates are removed during the update and must be replaced with certificates using at least 2048-bit RSA or ECC keys. Services relying on weaker certificates will stop functioning, and a warning will appear next to the certificate selection parameter in the web interface. New Functions and Improvements Devices can now generate Certificate Signing Requests (CSR) directly from the web interface under System > Certificates > CSR. All SIP accounts now support additional backup proxy and registrar servers. Changing the web interface password now requires entering the current password. As a result, restoring a configuration will no longer change the password. Auto Provisioning can change the password only if the current one is still set to default. Essential Corrections Improved certificate handling. The `OutputChanged` Automation block in Sentrio Cabin now displays the correct outputs. The `CallSessionStateChanged` event now triggers correctly for both Checking and Operational Calls. Prevented some certificates from reverting to factory defaults after a software factory reset (without selecting Network Settings), avoiding potential network disconnection. SIP unregistration now works correctly with non-RFC-compliant User Agent Servers. Removed certain unnecessary syslog messages. Improved formatting of exported Directory CSV files. SIP authentication passwords can now be up to 255 characters in length. DNS request lengths can now be up to 255 characters. Commas in the Subject field of the `SendEmail` Automation block no longer cause the subject line to be truncated. Fixed device crashes caused by missing Origin fields in SDP offers. SRTP media is now correctly offered in the ACK response when using delayed SDP negotiation enforced via options. When SRTP is re-negotiated during a RE-INVITE, the newly established encryption key is now properly applied to outgoing media streams. Improved stability of the G.729 codec. Improved SMTP reliability. Enhanced handling of large-scale user directory operations. Important bug fixes. |
| Tip | 10 – 30V DC (keep polarity), 48V PoE |
|---|---|
| PoE | 802.3af (Class 0–12.95 W) |
| Consum | Max. 2.5 W with integrated 16 Ω speaker, max. 3.5 W with external 4 Ω speaker (not included) |
| Inputs | 5 – 48V DC (keep polarity), NC/NO contacts |
|---|
| Difuzor | Integrated speaker 16 Ω / 1W (output power 0.45 W), option to increase the output power to 2.3 W by connecting a speaker with 4 Ω impedance |
|---|---|
| Microfon | Integrated, option to connect an external electret microphone |
| Audio | Full duplex, G.711 (approx 90kbit/s) |
| Induction loop output | 3.35V RMS, output impedance 100 Ω |
| Codecs | PCMU, PCMA, G.711 (approx. 90 kbps), L16, G.722 and G.729 |
| Voltage | 12 – 24V DC, external supply |
|---|---|
| Maximum current | 200mA (100 mA if a bulb is used) |
| Temperatură de funcționare | -20° – 50°C |
|---|
| 921640E, 92160XE - PCB version - hidden behind the COP | 65 × 130 × 24 mm |
|---|---|
| 921618E, 921618BE - COP design version - flush mount | 100 × 220 × 26 mm |
| 921619BE – COP design version – flush mount | 105 × 190 × 26 mm |
| 921640E - TOC long version - for installation on top of car with Voice alarm station switch | 82 × 257 × 33 mm |
| 921640XE - TOC short version - for installation on top of car w/o Voice alarm station switch | 82 × 186 × 33 mm |
| Length | 5 years (detailed terms: www.2n.com/warranty) |
|---|
Specificațiile sunt cele publicate de 2N, cu etichetele traduse în română (preluate la 05.11.2026). Ce nu am tradus a rămas în engleză.
Denumiri și variante: Lift IP 2.0
Videointerfon2N EasyGate IPFirmware V1.6.4.0.1 · 23.04.2026
Videointerfon2N EasyGate IP+Firmware V1.6.4.0.2 · 23.04.2026
Videointerfon2N Lift IP Service ToolFirmware V2.9.2 · 20.06.2025
Videointerfon2N Lift1Firmware V2.1.0.0.1 · 30.05.2025Videointerfon2N Lift8 Camera moduleFirmware V2.7.6 · 06.08.2025
Videointerfon2N Lift8 Service ToolFirmware V3.1.6 · 08.06.2026
Videointerfon2N LiftGateFirmware V1.15.3 · 23.04.2026Videointerfon2N LiftIPFirmware V2.8.7 · 06.08.2025Videointerfon2N Sentrio CabinFirmware V3.3.1 · 31.08.2026Videointerfon2N Sentrio LobbyFirmware V3.3.1 · 31.08.2026
Videointerfon2N Call CenterFără firmware publicVideointerfon2N Easygate IP Gsm Gateway 4g LTE Networks Adapter With Cable No Plug UsFără firmware public